Fair

Power cooling  Btu/h 7707 - kW 2,26 - EER 3,01 - EEC B
Power heating  Btu/h 8798 - kW 2,58- COP 3,63 - EEC A
Dehumidifying l/h 1,2
Air flow internal unit  high speed m³/h 390 / 420
Suction Ø 3/8"
Discharge Ø 1/4"
Power supply 230 V / 1 Ph / 50 Hz
Power input cooling kW 0,75
Power input heating kW 0,71
Running curr. cooling amp 3,5
Running curr. heating amp 3,4
Noise level 4 (distance 1 mts) dB(A) U.I. 26-36 / 29-36 - U.E. 41 / 42
Compressor R
Indoor unit dimensions wxhxd mm 795 x 265 x 175
Indoor unit weight Kg 7,2
Outdoor unit dimensions wxhxd mm 640 x 490 x 210
Outdoor unit weight Kg 24
Cooling capacity refers to an indoor temperature of 27 °C measured with dry bulb thermometer 19 °C measured with wet bulb thermometer and outdoor temperature of 35 °C (d.b.).
Heating capacity refers to an indoor temperature of 20 °C measured with dry bulb thermometer and an outdoor temperature of 7 °C measured with dry bulb thermometer and 6 °C measured with wet bulb thermometer.
Air flow rate in cooling mode / in heating mode.
Noise level in cooling mode / in heating mode.
R =
Rotary Compressor EEC = Energy Efficiency Class.